Troubleshooting Fibre Channel host bus adapters in PCs


Rick Cook
01.12.2004
Rating: -4.25- (out of 5)


Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


Installing a Host Bus Adapter (HBA) to connect a desktop system to a SAN doesn't always go smoothly and you can waste a lot of time getting the card to work. The good news is that almost always the problem results from one of a limited number of conditions, and by taking a layered, methodical approach you can get the HBA working in short order.

The first step, of course, is to see just where in the connection process the card is failing. Each step, from being recognized by the BIOS to logging into the Fibre Channel switch, has its own set of possible problems. By identifying where in the start up sequence the HBA is failing you can narrow down the possibilities.

A check of the BIOS scan will show if the PC is recognizing that the card is installed. If the HBA doesn't show up on the BIOS, the most common cause is that the card isn't properly seated and the problem can usually be resolved by re-seating the card. Another possibility is that for some reason that HBA won't work in that slot. Try the adapter in another slot.

The third common cause of failure on the BIOS level is that the firmware has become corrupted. Most modern HBAs use flash memory to store firmware, so this problem can be fixed by downloading the latest version of the firmware from the vendor site and re-installing it on the card according to the manufacturer's instructions.

Once the BIOS recognizes the card, it has to be seen by the operating system. If the operating system doesn't find the HBA, but the BIOS does, the problem is usually with the HBA driver. Make sure the driver is properly installed and re-install if necessary. Also check the driver version and the firmware version (usually displayed on the BIOS scan) to make sure they match. If they don't, get the appropriate versions from your vendor.

If you get this far and the system freezes on startup, suspect either another cable problem or a device conflict. Disconnect the devices from the HBA and reboot. If the problem goes away, check the connections carefully. If the problem persists, start pulling non-vital cards from the system to check for a PCI bus conflict. If you still have a problem, try the HBA in another machine. If it works there, consider the possibility of a conflict between the PC and the HBA. Use the card's setup utility to check for conflicts and resolve them before reinstalling the HBA.

Problems logging into the SAN with a new HBA most often either cable-related or port related. The cure for cable problems is to inspect, clean and repair or replace the cables. The most common kind of port problem is a mismatch between the port and the HBA, for example trying to use an HBA configured for an FL_Port (fabric loop) port on an F port. Make sure you know which kind of port you're trying to connect to and then configure the HBA for that port.

ATTO Technology describes the process of troubleshooting Fibre Channel HBA installations in a technical note on its web site at http://www.attotech.com/pcfc.html

Rick Cook has been writing about mass storage since the days when the term meant an 80K floppy disk. The computers he learned on used ferrite cores and magnetic drums. For the last twenty years he has been a freelance writer specializing in storage and other computer issues.

For more information on this topic:

This three-part tip offers more advice on installing, configuring and maintaining Fibre Channel HBAs: http://searchstorage.techtarget.com/originalContent/0,289142,sid5_gci922503,00.html
Featured topic: Solving HBA headaches:
http://searchstorage.techtarget.com/featuredTopic/0,290042,sid5_gci922515,00.html
This white paper details the critical role HBAs play in SANs: http://searchstorage.techtarget.com/whitepaperPage/0,293857,sid5_gci884711,00.html


Rate this Tip
To rate tips, you must be a member of SearchStorage.com.
Register now to start rating these tips. Log in if you are already a member.




Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


<< PREVIOUS | NEXT >>: How many HBA adapters are required in a SAN...
VIEW ALL IN THIS CATEGORY

RELATED CONTENT
Fibre Channel (FC) SAN
Here comes 8Gig Fibre Channel
SAS bumps up speed to 6Gigs
FCoE: Coming to a data center near you: Hot Spots
Change that stands the test of time: Best Practices
No open-and-shut case for NAS gateways
QLogic gives 8 Gbit capability to SANbox 9000 FC switch
Brocade waves caution flag for Fibre Channel over Ethernet
Ad agency chooses Compellent SAN for VMware DR project
Storage Decisions Chicago 2008 Session Downloads
Storage Decisions Session Downloads: Storage Systems & Networking Track (Chicago 2008)

SAN/NAS Update
Determining the number of drives in a RAID group
How to determine the protocol for your SAN
What you need to know before implementing NAS clusters
How to create an RFP for NAS
Planning for NAS
How to size a SAN
Understanding NAS interconnects: Fast Ethernet and Gigabit Ethernet
Why NAS protocols are the language of NAS
NAS remains simple and cost-effective
Dispelling myths about clustering NAS and file servers

SAN/NAS Technical Tips
Implementing SAS storage
Troubleshooting your NAS system
Guidelines for controlling clustering
Storage 101: Using a director switch
Better performance -- RAID striping or concatenation?
How to safely relocate your SAN
Crash Course: Snapshots
Using clusters to ensure failover
Storage Smarts Quiz: RAID
Zoning 101: Why zone?

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
enterprise storage  (SearchStorage.com)
Fast Guide to Storage Technologies  (WhatIs.com)
FCoE (Fibre Channel over Ethernet)  (SearchStorage.com)
Fibre Channel  (SearchStorage.com)
Fibre Channel over IP  (SearchStorage.com)
host bus adapter  (SearchStorage.com)
iFCP  (SearchStorage.com)
IP storage  (SearchStorage.com)
SAN island  (SearchStorage.com)
storage area network  (SearchStorage.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary

DISCLAIMER: Our Tips Exchange is a forum for you to share technical advice and expertise with your peers and to learn from other enterprise IT professionals. TechTarget provides the infrastructure to facilitate this sharing of information. However, we cannot guarantee the accuracy or validity of the material submitted. You agree that your use of the Ask The Expert services and your reliance on any questions, answers, information or other materials received through this Web site is at your own risk.

TechTarget Storage Media
Storage Magazine View this month\\'s issue and subscribe today.
Storage Decisions Apply online for free conference admission.
SearchStorage.com
HomeNewsMagazineTopicsLearningWebcastsWhite PapersBlogsEventsAbout Us

About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Reprints  |  Site Map




All Rights Reserved, Copyright 2000 - 2008, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts