RAID, as you've most likely noticed, is changing in the enterprise. Fibre Channel (FC) disks still provide the high-reliability and performance that they are renowned for, but a greater selection of disk types and advances in storage hardware are impacting the way that IT departments deploy RAID. Rapid growth and larger drive capacities are also influencing RAID rebuild times and constraining performance in some environments. Storage administrators must understand the changes that are taking place, and position their organizations to make the most of RAID technology. This article examines the effect of new disk types on RAID deployments, outlines the changing implementation issues and problems that you can expect, and highlights the future trends of this essential storage practice.

The impact of disk technology on RAID

RAID Information
RAID explained

The new breed of RAID controllers

Disk Storage All-In-One Guide

All storage systems can benefit from the reliability and performance that RAID offers, but the disks themselves have no direct impact on RAID choices. The ultimate choice of RAID implementation depends on the value of data that needs protecting and the performance needs of any applications using a given RAID group. While drive technologies do not necessitate specific RAID levels, it's clear that certain drive types have a strong correlation to common RAID levels.

Enterprise-class FC drives traditionally employed RAID-1 for basic mirroring, but most FC RAID groups will now use a parity-based approach, such as RAID-5, since fewer drives are required. If performance must be optimized, striping can be added to the RAID group using RAID-0 (e.g., RAID-1+0 or RAID-5+0).

As with other drive technologies, FC drives are offering larger storage capacities, and this is causing users to place fewer drives into FC RAID groups. For example, there may be up to eight 36 GB or 73 GB 15K rpm drives in a basic FC RAID group, but as FC drives have climbed to 146 GB and larger, users are employing only four or five drives in a given group. "This lower number is driven primarily by user concerns about the amount of time it takes to rebuild a failed disk drive on one of the global spares within the storage array," explains Jerome Wendt, independent storage industry analyst.

Although SATA drives offer lower performance than FC counterparts, their low cost and huge storage capacities have enabled a myriad of disk storage technologies, like continuous data protection (CDP), content addressed storage (CAS), virtual tape libraries (VTL) and others. This poses a unique problem for RAID because SATA drives suffer from reliability concerns, and capacities of 600 GB and larger can result in rebuild times easily exceeding several hours. This has forced many Tier-2 storage users to embrace dual-parity schemes, like RAID-6. "The cost of additional disk to provide this level of protection is not substantial," Wendt says. "And the likelihood of loosing two drives before the first drive rebuilds from a failure is a realistic possibility." SAS drives are not commonly deployed in RAID groups, though this may change as SAS technology continues into the mainstream.

The role of RAID levels

A "RAID level" defines the technique that is used to provide redundancy and performance enhancement to the drive group. Numerous RAID levels have been tested and refined over the last 20 years, though only RAID-0, RAID-1, and RAID-5 are commonly used today. Analysts note that RAID selection is largely defined by the need for performance, economy and reliability.

When storage performance is the key priority, users typically turn to RAID-0 and RAID-1. If disk economy is the main criteria, users adopt RAID-5, which uses rotating parity and one additional disk to provide data protection. Parity data is then spread out among the drives in a group. If a disk in the group fails, the data on that disk can be reconstructed from parity data across the other disks. Unfortunately, parity must be calculated on the fly, and schemes like RAID-5 impose a performance penalty on write. "You need compute power to calculate that parity or to reconstruct," Schulz says. "On a normal read it shouldn't be an overhead." RAID-5 can be combined with RAID-0 to boost performance.

RAID-6 is quickly making inroads into storage arrays because of its reliability. RAID-6 is a dual-parity data protection scheme that places two unique parity regions on each disk. This protects against two simultaneous failures in the disk group -- a real possibility with large low-end SATA drives. "It makes enterprises much more comfortable about using SATA drives to house mission critical information that requires capacity and availability but not necessarily performance [such as CAS]," Wendt says. Unfortunately, RAID-6 requires two additional disks, and the write performance penalty is roughly twice that of RAID-5. Storage-intensive tasks using 500 GB to 750 GB drives can usually tolerate the write performance penalty because performance is typically not a high priority. RAID-6 can be combined with RAID-0 to boost performance. RAID-6 is not intended to supplant RAID-5 -- both levels solve different problems in the enterprise.

RAID is not an all-or-nothing choice. In actual practice, RAID levels are often tailored to meet the needs of particular storage tiers in the data center. "These different tiers will typically have different RAID configurations," says Tony Asaro, senior analyst at the Enterprise Strategy Group. "Tier-1 could have RAID-10, and then Tier-2 could use RAID-5."

Go to the next page of this article for implementation issues and future directions



BROWSE BY TAG
SAN management,   SAN (storage area network),   Primary Storage or Storage Hardware,   RAID,   Disk drives,   Storage Area Network,   Storage area network management,   Storage area network monitoring/troubleshooting,   Resource Library,   Storage explained,   Disk Storage,   RAID,   RAID levels/explainers,   VIEW ALL TAGS

Digg This!    StumbleUpon Toolbar StumbleUpon    Bookmark with Delicious Del.icio.us   


<< PREVIOUS | NEXT >>
VIEW ALL IN THIS CATEGORY


RELATED CONTENT
SAN management
Unilever maintains 5 PB Fibre Channel SAN storage performance with Virtual Instruments' NetWisdom
Storage Decisions Chicago 2009 Session Downloads
Storage Decisions Session Downloads: Managing Storage Networks Track (Chicago 2009)
Storage-area networks to become increasingly object based
Data storage management in virtual server environments
10 Gb Ethernet bodes well for iSCSI
Mellanox builds bridge to consolidation
Best storage Products of the Year 2008
Wide stripe before you dive into SSD
How your SAN will evolve
SAN management Research

RAID
Pivot3 and Seanodes increase performance, scalability of iSCSI storage products
Fujitsu adds DX60 and DX80 midrange disk arrays to Eternus line
Storage Decisions Chicago 2009 Session Downloads
MAID technology remains underutilized
The state of MAID in data centers
MAID product roundup
The evolution of RAID data protection
RAID changes its stripes, but not its value
Post-RAID products
Faster disk drive rebuilds: Hot Spots
RAID Research

Disk drives
How to add solid-state storage to your enterprise data storage systems
Hot storage technologies for 2010
Enterprise data storage technologies rise from the dead
Fail-in-place systems: Avoiding hard disk drive failures
Dataram enters solid-state storage market with XcelaSAN
Pliant claims up to 180,000 IOPS per drive with new Lightning Enterprise Flash Drive
Low-cost MLC NAND flash gains in enterprise solid-state storage
Solid-state storage update
STEC Inc. CTO looks at the future of flash and solid-state drives
STEC ships enterprise-ready MLC solid-state drives, but acknowledges tradeoffs
Disk drives Research

RELATED GLOSSARY TERMS
Terms from Whatis.com − the technology online dictionary
Fast Guide to Storage Technologies  (WhatIs.com)
fat provisioning  (SearchStorage.com)
oversubscription  (SearchStorage.com)
RAID  (SearchStorage.com)
storage area management  (SearchStorage.com)
storage area network  (SearchStorage.com)
thin provisioning  (SearchStorage.com)
unified storage  (SearchStorage.com)
virtual provisioning  (SearchStorage.com)
zoned-bit recording  (SearchStorage.com)

RELATED RESOURCES
2020software.com, trial software downloads for accounting software, ERP software, CRM software and business software systems
Search Bitpipe.com for the latest white papers and business webcasts
Whatis.com, the online computer dictionary




Find Data Reduction
TechTarget Storage Media
Storage Magazine View this month\\'s issue and subscribe today.
Storage Decisions Apply online for free conference admission.
SearchStorage.com
HomeNewsMagazineTopicsLearningMultimediaWhite PapersBlogsEventsAbout Us

About Us  |  Contact Us  |  For Advertisers  |  For Business Partners  |  Site Index  |  RSS
TechTarget provides technology professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective purchase decisions and managing their organizations' technology projects - with its network of technology-specific websites, events and online magazines.

TechTarget Corporate Web Site  |  Media Kits  |  Site Map




All Rights Reserved, Copyright 2000 - 2009, TechTarget | Read our Privacy Policy
  TechTarget - The IT Media ROI Experts