Troubleshooting clustered server issues

Troubleshooting clustered server issues

I have a two-node clustered server. Both servers have two host bus adapters (HBAs) connected to two fabric switches and to a redundant SAN controller. My problem is only one path has connectivity to storage device, HBA 1 of server 1 and HBA 1 of server 2 has no connectivity to storage device. Both fabric switches are working fine. What could be wrong, can you help me?

    Requires Free Membership to View

    When you register for SearchStorage.com, you’ll also receive targeted emails from my team of award-winning editorial writers. Our goal is to keep you informed on the hottest topics, the latest news and the biggest challenges you face as a storage professional today.

    Rich Castagna, Editorial Director

    By submitting your registration information to SearchStorage.com you agree to receive email communications from TechTarget and TechTarget partners. We encourage you to read our Privacy Policy which contains important disclosures about how we collect and use your registration and other information. If you reside outside of the United States, by submitting this registration information you consent to having your personal data transferred to and processed in the United States. Your use of SearchStorage.com is governed by our Terms of Use. You may contact us at webmaster@TechTarget.com.

Since I do not know enough about your environment to give you definitive answers, here are some things you can look at. Let's start with some procedural questions. Can your Fibre Channel (FC) switches see/discover HBA 1 in both servers? If not, that would explain your problem. What multipathing software are you running on your servers? (MPIO, PowerPath, DMP, etc.) Is it compatible with your target storage? If you do not have multipathing software, that could explain your problem. If you do, and it is not compatible with your target storage, that also could explain your problem. How are your HBAs and target storage ports zoned? If HBA 1 of both servers are not correctly zoned to the right target storage ports, that too will cause your problem.

There is currently only one software package on the market that can instantly diagnose your problem. It is called SANScreen from Onaro. It is a bit pricey and typically only cost justifies for SANs larger than 128 ports.

You can also contact your server, HBA, multipath software, FC switch or target storage vendor for troubleshooting help.

This was first published in December 2005