Connecting multimode fiber cable to single mode

Connecting multimode fiber cable to single mode

Can you connect one segment of MMF to another segment of SMF? What problems would this present?

    Requires Free Membership to View

    When you register for SearchStorage.com, you’ll also receive targeted emails from my team of award-winning editorial writers. Our goal is to keep you informed on the hottest topics, the latest news and the biggest challenges you face as a storage professional today.

    Rich Castagna, Editorial Director

    By submitting your registration information to SearchStorage.com you agree to receive email communications from TechTarget and TechTarget partners. We encourage you to read our Privacy Policy which contains important disclosures about how we collect and use your registration and other information. If you reside outside of the United States, by submitting this registration information you consent to having your personal data transferred to and processed in the United States. Your use of SearchStorage.com is governed by our Terms of Use. You may contact us at webmaster@TechTarget.com.

First of all, let's get the acronyms out of the way. An MMF (multimode fiber) cable connection is used for standard SAN connectivity between a server and a SAN switch, or a storage device and a SAN switch. An SMF (single mode fiber) connection is normally used to connect SAN switches together over distance to form a larger SAN fabric. The difference between the two connection types is the frequency of the laser optics, and the diameter of the optical cable. SMF type connections are rated at longer distances than MMF connections.

SMF connections are also used in the latest FICON connections for mainframes. Older mainframe connections used larger cable cores in the 62.5 micron range. The chart below may help you with the differences.

Each connection type requires a specific GBIC (Gigabit interface converter), which is rated as a long-wave or short-wave laser. The Gigabit Interface Converter (GBIC) is where the cable plugs into the HBA card. Every HBA card has a GBIC that snaps into an opening in the card or is soldered into the card. The openings in the GBIC extend out of the back of the server, so you can plug in the cable. The GBIC houses the laser and electronics that convert the data inside your server into the light pulses that travel over the cables. GBICs are not used only in the HBA; they are used in every device in the SAN. Anywhere an optical cable needs to be plugged in, you will find a GBIC.

As for your question of whether one segment can be MMF and another SMF, the answer is yes, as long as the correct GBIC is used at the connection ends. Normally, this would be between two different switch ports. SMF connections are more expensive though, and are required only when the distance between devices are longer than supported by MMF connections. Therefore, there is no real advantage to using SMF unless you are connecting a mainframe via FICON, or need more distance between your devices and the switches. SMF connections are normally used between switches that connect data centers together into a single large fabric via a DWDM (Dense Wave Division Multiplexed) connection. These connections are sometimes referred to as "dark fiber", since it's harder to "see" the light if looking at the end of the cable. By the way, NEVER look into a fiber cable, since it WILL blind you.

Chris